In the realm of environmental regulations, the Central Pollution Control Board (CPCB) plays a pivotal role in setting and enforcing norms to control pollution from various sources, including diesel generator (DG) sets. One critical aspect that CPCB addresses is the stack height for DG sets. In this comprehensive guide, we will delve into CPCB norms for DG set stack height, exploring the calculations, factors, and implications of these regulations.
Stack Height Calculation for Coal-Fired Boilers
Stack height regulations vary depending on the type and capacity of the equipment. The stack height is determined using a specific formula based on the emission of sulfur dioxide (SO2) in kilograms per hour (kg/hr). The formula for calculating the physical height of the stack (H) is as follows:
H = 14(Qg)
Where:
- H is the physical height of the stack.
- Qg is the emission of sulfur dioxide (SO2) in kg/hr.
Now, let's break down how this formula is applied to different scenarios based on steam generation capacity and coal consumption.
Steam Generation Capacity vs. Stack Height
Steam Generation Capacity | Coal Consumed | Stack Height |
---|---|---|
Less than 2 ton/hr | 8.5 MT/day | 2 & 1/2 times the neighboring building height or 9 meters (whichever is more) |
More than 2 ton/hr to 5 ton/hr | 8.5 MT/day to 21 MT/day | 12 meters |
More than 5 ton/hr to 10 ton/hr | 21 MT/day to 42 MT/day | 15 meters |
More than 10 ton/hr | 42 MT/day to 64 MT/day | 18 meters |
More than 15 ton/hr to 20 ton/hr | 64 MT/day to 104 MT/day | 21 meters |
More than 20 ton/hr to 25 ton/hr | 104 MT/day to 105 MT/day | 24 meters |
More than 25 ton/hr to 30 ton/hr | 105 MT/day to 126 MT/day | 27 meters |
More than 30 ton/hr | More than 126 MT/day | 30 meters (whichever is more) or using formula H = 14(Qg) |
These regulations establish a clear relationship between steam generation capacity, coal consumption, and stack height for coal-fired boilers. However, it's important to note that this formula applies specifically to steam generating boilers.
Stack Height for Industrial Furnaces and Kilns
When it comes to industrial applications other than boilers for steam and power generation, the criteria for selecting equipment is based on coal usage, similar to the method mentioned in 2.2 above. The stack height for these applications should follow the norms outlined in CPCB regulations.
Applicability to Existing and New Industries
CPCB norms for stack height are not limited to new industries; they also apply to existing ones. Existing industries must make necessary modifications to their plants to accommodate new chimneys and control equipment, ensuring compliance with the specified stack height requirements.
Relaxation of Stack Height for Emission Control
For industries that install facilities to remove particulates or gaseous emissions and adhere to prescribed limits, CPCB allows for the relaxation of stack height requirements. In such cases, the formula for stack height relaxation is as follows:
- For gaseous emissions (Og in kg/hr): H = 14(Og)
- For particulate emissions (Op in kg/hr): H = 74(Op)
These relaxations are contingent upon meeting the emissions limits specified in CPCB regulations.
Minimum Stack Height Requirement
Regardless of the calculations and relaxations, CPCB mandates that the minimum height of the stack in all cases shall be 9.0 meters (30 feet) or as calculated by the relevant formula, whichever is greater.
PDF Download:
click here to download pdf
Conclusion
Understanding CPCB norms for DG set stack height is essential for industries and businesses to ensure compliance with environmental regulations. Stack height regulations not only control pollution but also contribute to a cleaner and healthier environment. By adhering to these regulations and making the necessary modifications, industries can play their part in reducing the environmental impact of their operations. Stay informed about updates and amendments to CPCB norms to ensure continued compliance and responsible use of DG sets.
CPCB Norms for DG Set Stack Height: FAQs
Q1: What are CPCB norms for DG set stack height?
CPCB (Central Pollution Control Board) norms for DG set stack height are regulations that specify the required height of the exhaust stack for diesel generator sets based on factors like steam generation capacity, coal consumption, and emissions. These norms are designed to control pollution and ensure environmental compliance.
Q2: How is stack height calculated for DG sets?
Stack height for DG sets, particularly for coal-fired boilers, is calculated using the formula H = 14(Qg), where H represents the physical height of the stack, and Qg is the emission of sulfur dioxide (SO2) in kilograms per hour (kg/hr). The formula helps determine the stack height required to disperse emissions effectively.
Q3: Do these norms apply to all types of industries?
CPCB norms for stack height primarily apply to industries using DG sets, especially those with coal-fired boilers for steam generation. However, they can also apply to other industrial applications based on coal usage, such as industrial furnaces and kilns.
Q4: Are these norms applicable to existing industries as well?
Yes, CPCB norms for stack height apply to both existing and new industries. Existing industries must make necessary modifications to meet the specified stack height requirements and ensure compliance.
Q5: Can stack height requirements be relaxed for emissions control?
Yes, CPCB allows for stack height relaxation in certain cases when industries install facilities to control particulates or gaseous emissions and meet prescribed limits. The relaxation depends on the type and amount of emissions controlled.
Q6: What is the minimum stack height requirement according to CPCB norms?
CPCB mandates that the minimum stack height for DG sets in all cases shall be 9.0 meters (30 feet) or as calculated by the relevant formula, whichever is greater. This ensures a baseline for pollution control.
Q7: Where can I find the latest updates and amendments to CPCB norms?
You can find the latest updates and amendments to CPCB norms on the official website of the Central Pollution Control Board (CPCB) in India. Additionally, staying informed about environmental regulations through industry news and consulting with environmental experts is advisable.
Q8: How can industries ensure compliance with CPCB stack height norms?
Industries can ensure compliance with CPCB stack height norms by conducting stack height calculations based on their specific equipment and emissions, making necessary modifications to meet requirements, and regularly monitoring emissions to stay within prescribed limits. Consulting with environmental experts is often beneficial.
Q9: What is the significance of adhering to CPCB stack height norms?
Adhering to CPCB stack height norms is significant because it helps industries reduce their environmental impact by controlling emissions effectively. It also ensures compliance with environmental regulations, contributing to a cleaner and healthier environment for all.
Q10: Are there penalties for non-compliance with CPCB stack height norms?
Yes, there can be penalties for non-compliance with CPCB stack height norms. Industries failing to meet these norms may face fines, legal actions, or shutdown orders, depending on the severity of violations. It is crucial for industries to prioritize compliance to avoid such consequences.